Omega Altise Indoor Gas Heater Troubleshooting
Omega Altise Brigadier
Omega Altise Lancer
Problem
Spark Failure
Probable Cause
Faulty Igniter/Incorrect Spark Gap/Loose or Faulty Connections
Suggested Remedy
Service required, Resent to 4.5mm, Check with meter
Problem
Failure to ignite even with spark present
Probable Cause
No Gas/Incorrect injectors/Incorrect gas type/Air in gas lines/Faulty thermocouple/Faulty tilt switch
Suggested Remedy
Check supply, Service required, Check gas for which unit was intended, Service required (Replacement required injector/thermocouple/tilt switch/ ODS)
Problem
Dull or uneven burners
Probable Cause
Partially blocked injectors/Burner venturi blocked/Dirty burner tiles
Suggested Remedy
Service required, Clean/replace injectors
Problem
Burner flashing back
Probable Cause
Cracked burner tile/Faulty or incorrect injectors/Injector loose
Suggested Remedy
Service required, Replace burner tile, Replace or tighten injector
Problem
Very high pilot flame
Probable Cause
Pilot ports partially blocked
Suggested Remedy
Clean with compressed air or vacuum cleaner